Customer in Keller at a Baskin-Robbins called For AC repair because the air conditioning drain lines were leaking into the store front. We arrived to find water dripping from light fixtures, AC vents, and ceiling tiles. We went up on the roof and took the drains apart and found that the primary nipple that attaches to the evaporator coil drain pan was clogged. We remove the clog and put the drains back together and visualized water flowing through the drains into the sink in the store which confirmed that the drains were clear and operating as designed. We left the system cooling and operational.

Near Rufe Snow Dr, Fort Worth, TX 76148
Fort Worth, TX - Customer in Keller at a Baskin-Robbins called For AC repair because the air conditioning drain lines were leaking into the store front. We arrived to find water dripping from light fixtures, AC vents, and ceiling tiles. We went up on the roof and took the drains apart and found that the primary nipple that attaches to the evaporator coil drain pan was clogged. We remove the clog and put the drains back together and visualized water flowing through the drains into the sink in the store which confirmed that the drains were clear and operating as designed. We left the system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Bedford called for an AC repair because the outdoor unit for his air conditioner was no longer functioning. The condenser fan motor has stopped spinning and the entire unit was hot to the touch. We arrived to find a 17 year old train gas furnace HVAC system with a failed compressor and condenser fan motor. Upon further investigation we found that the system was on R-22 refrigerant and had a slab coil that also need to be replaced. We quoted for a full system replacement and just replacing the condenser and evaporator coil. We will be installing the system he chooses tomorrow.

Near Mayfair Hill Ct, Bedford, TX 76021
Bedford, TX - A homeowner in Bedford called for an AC repair because the outdoor unit for his air conditioner was no longer functioning. The condenser fan motor has stopped spinning and the entire unit was hot to the touch. We arrived to find a 17 year old train gas furnace HVAC system with a failed compressor and condenser fan motor. Upon further investigation we found that the system was on R-22 refrigerant and had a slab coil that also need to be replaced. We quoted for a full system replacement and just replacing the condenser and evaporator coil. We will be installing the system he chooses tomorrow.
Nicholas R.

Nicholas R.

A homeowner in Grapevine called for AC repair because his drains were acting up. We arrived to find a 14 year old American standard gas HVAC system and air conditioner with light water dripping from the case of the evaporator coil. We opened up the cased coil and confirmed that the primary drain pan did not have a crack and was not leaking, we then checked the drains and visualized water flowing through them so we knew they weren’t clogged. We then checked the refrigerant levels to make sure that the Freon wasn’t low and that the coil wasn’t freezing up. Our final diagnosis was that the metal on the evaporator case was below dewpoint and creating condensation that was slowly dripping off into the pan. We insulated to reduce condensation and then left the system cooling and operational.

Near Branchwood Dr, Grapevine, TX 76051
Grapevine, TX - A homeowner in Grapevine called for AC repair because his drains were acting up. We arrived to find a 14 year old American standard gas HVAC system and air conditioner with light water dripping from the case of the evaporator coil. We opened up the cased coil and confirmed that the primary drain pan did not have a crack and was not leaking, we then checked the drains and visualized water flowing through them so we knew they weren’t clogged. We then checked the refrigerant levels to make sure that the Freon wasn’t low and that the coil wasn’t freezing up. Our final diagnosis was that the metal on the evaporator case was below dewpoint and creating condensation that was slowly dripping off into the pan. We insulated to reduce condensation and then left the system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Colleyville called for ac repair complaining that his air conditioner was blowing but not cooling. We arrived to find an 11 year old Trane AC condenser where the fan motor was not turning. Upon further investigation we found that the condenser capacitor was out of range. We replaced with a turbo 200 that has a 5-year warranty and the unit ran as designed. Left system cooling and operational.

Near Briar Ridge Dr, Colleyville, TX 76034
Colleyville, TX - A homeowner in Colleyville called for ac repair complaining that his air conditioner was blowing but not cooling. We arrived to find an 11 year old Trane AC condenser where the fan motor was not turning. Upon further investigation we found that the condenser capacitor was out of range. We replaced with a turbo 200 that has a 5-year warranty and the unit ran as designed. Left system cooling and operational.
Nicholas R.

Nicholas R.

Came out to a Home in Colleyville to do a final inspection on a new gas furnace and air conditioner that we installed. Took photos and did the quality check checklist to confirm a successful installation. This is a 14 seer American standard unit.

Near Hardage Ln, Colleyville, TX 76034
Colleyville, TX - Came out to a Home in Colleyville to do a final inspection on a new gas furnace and air conditioner that we installed. Took photos and did the quality check checklist to confirm a successful installation. This is a 14 seer American standard unit.
Nicholas R.

Nicholas R.

A homeowner in Keller called for ac repair complaining that the blower motor in their Rheem Heat Pump was squealing. We arrived to find that the blower motor had a foreign object lodged in it. We slid the blower motor housing out and removed the foreign object and ran the air conditioner without incident. Left the system cooling and operational.

Near Corral Dr, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called for ac repair complaining that the blower motor in their Rheem Heat Pump was squealing. We arrived to find that the blower motor had a foreign object lodged in it. We slid the blower motor housing out and removed the foreign object and ran the air conditioner without incident. Left the system cooling and operational.
Nicholas R.

Nicholas R.

The homeowner in Southlake called for ac repair and said his tenant complained that the air conditioner for the master bedroom and office was not cooling. We arrived to find a Carrier gas HVAC system that was blowing but not cooling. The system had 65psi of R-410a on the suction line and an evaporator temperature of 14 degrees. We turned off the AC and left the fan running to thaw the evaporator coil and once that was thawed we added refrigerant to get the pressures and temperatures back into manufacturer’s recommended specifications. We did inform the landlord that the system had a leak that needed to be found but he requested we just charge the system. Left system cooling and operational.

Near Logans Ln, Southlake, TX 76092
Southlake, TX - The homeowner in Southlake called for ac repair and said his tenant complained that the air conditioner for the master bedroom and office was not cooling. We arrived to find a Carrier gas HVAC system that was blowing but not cooling. The system had 65psi of R-410a on the suction line and an evaporator temperature of 14 degrees. We turned off the AC and left the fan running to thaw the evaporator coil and once that was thawed we added refrigerant to get the pressures and temperatures back into manufacturer’s recommended specifications. We did inform the landlord that the system had a leak that needed to be found but he requested we just charge the system. 
Left system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Keller called complaining that the secondary drain for her air conditioner was dripping outside and that the AC wasn’t keeping up inside. We arrive to find a seven year old Rheem gas HVAC system they had a clogged primary drain and a condenser that was very dirty. We flushed the drain lines and confirmed good water flow and then went outside and professionally cleaned the condenser from the inside out. Once we finish the work we confirmed a 15° temperature split indoors letting us know that the AC repair was successful and that system is cooling as designed. Left system cooling and operational.

Near Niles Ct, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called complaining that the secondary drain for her air conditioner was dripping outside and that the AC wasn’t keeping up inside. We arrive to find a seven year old Rheem gas HVAC system they had a clogged primary drain and a condenser that was very dirty. We flushed the drain lines and confirmed good water flow and then went outside and professionally cleaned the condenser from the inside out. Once we finish the work we confirmed a 15° temperature split indoors letting us know that the AC repair was successful and that system is cooling as designed. Left system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Keller called complaining that the secondary drain for her air conditioner was dripping outside. We arrived to find a 10 year old Amana gas HVAC system with a primary drain clogged. Upon further investigation we found that the system needed a drain blowout valve, a float switch installed to local code minimums, and the auxiliary pan to be re-leveled so it would drain appropriately. Homeowner approved all the work so we made the AC repair and got the system back within manufacturers specifications and local code ordinances. We left the system cooling an operational.

Near Aidan Ct, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called complaining that the secondary drain for her air conditioner was dripping outside. We arrived to find a 10 year old Amana gas HVAC system with a primary drain clogged. Upon further investigation we found that the system needed a drain blowout valve, a float switch installed to local code minimums, and the auxiliary pan to be re-leveled so it would drain appropriately. Homeowner approved all the work so we made the AC repair and got the system back within manufacturers specifications and local code ordinances. We left the system cooling an operational.
Nicholas R.

Nicholas R.

A customer in Keller called for an ac repair because their air conditioner was not blowing much air. We arrived to find a 12 year old Trane HVAC system that had moderate to low airflow. When we opened up the air handler we found that the blower motor was working fine and that the amps were within range. What we found was that the evaporator coil was frozen which was not allowing air to get through. We turned off the AC and left the blower running to thaw the unit and then did a leak check.

Near Muir Dr, Fort Worth, TX 76244
Fort Worth, TX - A customer in Keller called for an ac repair because their air conditioner was not blowing much air. We arrived to find a 12 year old Trane HVAC system that had moderate to low airflow. When we opened up the air handler we found that the blower motor was working fine and that the amps were within range. What we found was that the evaporator coil was frozen which was not allowing air to get through. We turned off the AC and left the blower running to thaw the unit and then did a leak check.
Nicholas R.

Nicholas R.

Customer called stating that another company came out due to a float switch cutting power to his nest thermostat. The company cleared the drains got power back to the thermostat and the system operating but then told him that the compressor was failing and he needed a new system. He asked us to come give him a second opinion. We arrived to find an eight year old carrier heat pump that was operational. Upon further investigation we found that the compressor megaohms were 1000 which is great, that the individual leads to the motor ohmed out perfectly, but that the capacitor was out of range. We completed the ac repair by replacing the capacitor and left the system cooling and operational

Near Loreto Dr, Fort Worth, TX 76177
Fort Worth, TX - Customer called stating that another company came out due to a float switch cutting power to his nest thermostat. The company cleared the drains got power back to the thermostat and the system operating but then told him that the compressor was failing and he needed a new system. He asked us to come give him a second opinion. We arrived to find an eight year old carrier heat pump that was operational. Upon further investigation we found that the compressor megaohms were 1000 which is great, that the individual leads to the motor ohmed out perfectly, but that the capacitor was out of range. We completed the ac repair by replacing the capacitor and left the system cooling and operational
Nicholas R.

Nicholas R.

Homeowner in Keller called for ac repair complaining that the air conditioner was blowing but not cooling. We arrived to find a two year old Rheem gas HVAC system that was low on refrigerant. We did initial leak detection and found a loose connection so we tightened that and then topped off the refrigerant. Left the system cooling and operational.

Near Postwood Dr, Fort Worth, TX 76244
Fort Worth, TX - Homeowner in Keller called for ac repair complaining that the air conditioner was blowing but not cooling. We arrived to find a two year old Rheem gas HVAC system that was low on refrigerant. We did initial leak detection and found a loose connection so we tightened that and then topped off the refrigerant. Left the system cooling and operational.
Nicholas R.

Nicholas R.

The homeowner in Bedford called for ac repair complaining that their air conditioner was blowing but not cooling. Arrived to find a 25 year old R-22 gas HVAC system that was tripping at the condenser on high-pressure. We tested the pressures and the temperatures of the outdoor unit and everything was within manufacturers recommended specifications. Turns out that the nest thermostat was the cause by short cycling the system and dropping the call for cool. Recommended the homeowner replace the thermostat, we left the system cooling and operational.

Near Ashbury Ln, Bedford, TX 76021
Bedford, TX - The homeowner in Bedford called for ac repair complaining that their air conditioner was blowing but not cooling. Arrived to find a 25 year old R-22 gas HVAC system that was tripping at the condenser on high-pressure. We tested the pressures and the temperatures of the outdoor unit and everything was within manufacturers recommended specifications. Turns out that the nest thermostat was the cause by short cycling the system and dropping the call for cool. Recommended the homeowner replace the thermostat, we left the system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Keller called for ac repair complaining that his downstairs air conditioner was freezing up. Arrived to find a 17 year old carrier gas HVAC system that was significantly low on Freon. We spoke to the homeowner about his options and he opted to replace the condenser and coil for the air conditioning side of the system. We are ordering the parts and will be installing the system tomorrow.

Near Postwood Dr, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called for ac repair complaining that his downstairs air conditioner was freezing up. Arrived to find a 17 year old carrier gas HVAC system that was significantly low on Freon. We spoke to the homeowner about his options and he opted to replace the condenser and coil for the air conditioning side of the system. We are ordering the parts and will be installing the system tomorrow.
Nicholas R.

Nicholas R.

A homeowner in Keller called complaining that the air conditioner was blowing but not cooling. We arrived to find a 4 year old Rheem gas HVAC system with the indoor unit running and the condenser not running. Upon further investigation we found that there was no call for cool on the outdoor unit. We troubleshot the furnace control board and found that the 3amp fuse had blown. We tested the system for a short and was not able to duplicate the issue. We replaced the furnace control board fuse for the ac repair and left the system cooling and operational.

Near Chaps Ave, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called complaining that the air conditioner was blowing but not cooling. We arrived to find a 4 year old Rheem gas HVAC system with the indoor unit running and the condenser not running. Upon further investigation we found that there was no call for cool on the outdoor unit. We troubleshot the furnace control board and found that the 3amp fuse had blown. We tested the system for a short and was not able to duplicate the issue. We replaced the furnace control board fuse for the ac repair and left the system cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Keller called complaining that her air conditioning drains weren’t functioning properly. We arrived to find a two year old Rheem gas HVAC system with water in the secondary drain pan. Upon further investigation we found that the primary was clogged and the secondary was dumping into the pan. We cleared the primary drain and waited till we visualized water successfully draining as designed. When complete the AC repair was fully functioning and we left the system cooling and operational.

Near Corral Cir, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller called complaining that her air conditioning drains weren’t functioning properly. We arrived to find a two year old Rheem gas HVAC system with water in the secondary drain pan. Upon further investigation we found that the primary was clogged and the secondary was dumping into the pan. We cleared the primary drain and waited till we visualized water successfully draining as designed. When complete the AC repair was fully functioning and we left the system cooling and operational.
Nicholas R.

Nicholas R.

A surgical center in Keller / North Fort Worth called for ac repair complaining that there was condensation dripping from one of the vents in a surgical room. Upon arrival we checked the temperature split and the temperature coming from the vent and tested the relative humidity and wet bulb in the room. And we found that the temperature of the supply grill was below the dewpoint. It turned out that all of the thermostats were reading 5° warmer than the actual air temperature in the room. This is causing the supply air temperature to be incredibly low which is the root cause of the condensation on the air conditioner vents.

Near N Beach St, Fort Worth, TX 76244
Fort Worth, TX - A surgical center in Keller / North Fort Worth called for ac repair complaining that there was condensation dripping from one of the vents in a surgical room. Upon arrival we checked the temperature split and the temperature coming from the vent and tested the relative humidity and wet bulb in the room. And we found that the temperature of the supply grill was below the dewpoint. It turned out that all of the thermostats were reading 5° warmer than the actual air temperature in the room. This is causing the supply air temperature to be incredibly low which is the root cause of the condensation on the air conditioner vents.
Nicholas R.

Nicholas R.

We returned to a home in Keller where we installed a new American standard complete gas HVAC system. This is a follow up trip to tune the air conditioner to make sure that we get the temperatures and pressures correct for the refrigerant. This helps to optimize the cooling and efficiency of the system. When we arrived we tuned everything within manufacturers recommended specifications and got the temperature split in the home to 18°. We left the system cooling and operational.

Near Archer Dr, Fort Worth, TX 76244
Fort Worth, TX - We returned to a home in Keller where we installed a new American standard complete gas HVAC system. This is a follow up trip to tune the air conditioner to make sure that we get the temperatures and pressures correct for the refrigerant. This helps to optimize the cooling and efficiency of the system. When we arrived we tuned everything within manufacturers recommended specifications and got the temperature split in the home to 18°. We left the system cooling and operational.
Nicholas R.

Nicholas R.

The homeowner in Colleyville called for ac repair complaining that his upstairs air conditioner was not cooling. We arrived to find a nine year old American standard Straight cool condenser that had a leak on the liquid line on the outdoor unit. We attempted a low percentage repair, that did not work. We recommended replacing the unit, and the homeowner agreed. We disconnected the condenser and will be installing the new one tomorrow.

Near Champion Way, Colleyville, TX 76034
Colleyville, TX - The homeowner in Colleyville called for ac repair complaining that his upstairs air conditioner was not cooling. We arrived to find a nine year old American standard Straight cool condenser that had a leak on the liquid line on the outdoor unit. We attempted a low percentage repair, that did not work. We recommended replacing the unit, and the homeowner agreed. We disconnected the condenser and will be installing the new one tomorrow.
Nicholas R.

Nicholas R.

Homeowner in Keller called for AC repair requesting that we do a full inspection of both systems. We changed the filters, checked all electrical connections, amped out all major components, verified that the drains were functioning correctly, washed the condensers, and check the refrigerant levels. We found that both condenser capacitor’s had failed, so we replace those with new ones. We also found that the upstairs air conditioner was low on refrigerant so we put 3 pounds in it. When we left all systems were operating within manufacture is recommended specifications. We left the systems cooling and operational.

Near Homestretch Dr, Fort Worth, TX 76244
Fort Worth, TX - Homeowner in Keller called for AC repair requesting that we do a full inspection of both systems. We changed the filters, checked all electrical connections, amped out all major components, verified that the drains were functioning correctly, washed the condensers, and check the refrigerant levels.
We found that both condenser capacitor’s had failed, so we replace those with new ones. We also found that the upstairs air conditioner was low on refrigerant so we put 3 pounds in it.
When we left all systems were operating within manufacture is recommended specifications. We left the systems cooling and operational.
Nicholas R.

Nicholas R.

A homeowner in Keller / Fort Worth called for AC repair complaining that the air conditioner was blowing but not cooling. We arrived to find a 16 year old Goodman complete gas HVAC system with a condenser fan motor that would not turn. Upon further investigation we found that the fan capacitor and the compressor capacitor were both bad. We replaced the capacitors and the fan still wouldn’t turn, it was seized up. We replaced the condenser fan motor and restarted the system and it ran as designed. Left system cooling and operational.

Near Sam Bass Ct, Fort Worth, TX 76244
Fort Worth, TX - A homeowner in Keller / Fort Worth called for AC repair complaining that the air conditioner was blowing but not cooling. We arrived to find a 16 year old Goodman complete gas HVAC system with a condenser fan motor that would not turn. Upon further investigation we found that the fan capacitor and the compressor capacitor were both bad. We replaced the capacitors and the fan still wouldn’t turn, it was seized up. We replaced the condenser fan motor and restarted the system and it ran as designed. Left system cooling and operational.
Nicholas R.

Nicholas R.

The homeowner in Colleyville called requesting an AC repair because their 12 year old American standard air conditioner wasn’t cooling properly. We arrived to find that the thermostat had failed and was not giving a call for cool. We replaced with a Honeywell T for pro and got the system operational. We did a complete check on the HVAC units and found everything to be within manufacturers recommended specifications.

Near Willow Ln, Colleyville, TX 76034
Colleyville, TX - The homeowner in Colleyville called requesting an AC repair because their 12 year old American standard air conditioner wasn’t cooling properly. We arrived to find that the thermostat had failed and was not giving a call for cool. We replaced with a Honeywell T for pro and got the system operational. We did a complete check on the HVAC units and found everything to be within manufacturers recommended specifications.
Nicholas R.

Nicholas R.

The homeowner in Colleyville called requesting an AC repair because their 11-year-old Trane condenser was not coming on. Upon further investigation we found that the capacitor had failed and the system was low on refrigerant. We added refrigerant and replaced the failed part and got the system up and running.

Near Willow Ln, Colleyville, TX 76034
Colleyville, TX - The homeowner in Colleyville called requesting an AC repair because their 11-year-old Trane condenser was not coming on. Upon further investigation we found that the capacitor had failed and the system was low on refrigerant. We added refrigerant and replaced the failed part and got the system up and running.
Nicholas R.

Nicholas R.

Homeowner in Colleyville called for ac repair complaining that their air conditioner was not keeping up. We arrived to find a Trane HVAC system that was running but was not cooling. Upon further investigation we found that the refrigerant levels were low. We did extensive leak detection and could not find the source of the leak, so we recommended using a UV dye with a leak stop help prevent the leak or in the worst case scenario help us find the leak the next time that it starts cooling. We then topped off the system with Freon and got it back to manufacturers recommended specifications. We left the system cooling an operational.

Near Shadowood Rd, Colleyville, TX 76034
Colleyville, TX - Homeowner in Colleyville called for ac repair complaining that their air conditioner was not keeping up. We arrived to find a Trane HVAC system that was running but was not cooling. Upon further investigation we found that the refrigerant levels were low. We did extensive leak detection and could not find the source of the leak, so we recommended using a UV dye with a leak stop help prevent the leak or in the worst case scenario help us find the leak the next time that it starts cooling. We then topped off the system with Freon and got it back to manufacturers recommended specifications. We left the system cooling an operational.
Nicholas R.

Nicholas R.

A commercial customer in Colleyville called complaining that the drains from one of their small refrigeration units had come undone. We are out to find the drains had disconnected and was leaking water on the floor. We cleaned out the water and repaired the drains, reconnecting them back to the small refrigerator.

Near Colleyville Blvd, Colleyville, TX 76034
Colleyville, TX - A commercial customer in Colleyville called complaining that the drains from one of their small refrigeration units had come undone. We are out to find the drains had disconnected and was leaking water on the floor. We cleaned out the water and repaired the drains, reconnecting them back to the small refrigerator.